# Vacuum Chamber Leak Rate: What 1e-9 mbar L/s Means

> Your RFQ says leak rate < 1×10⁻⁸ mbar·L/s: what the number means, how He-MS measures it, and how to write specs suppliers can meet.

https://www.sinbo-machining.com/wiki/applications/vacuum-chamber-leak-rate-rfq/

---

## On This Page

- What “Leak Rate < 1×10⁻⁸ mbar·L/s” Actually Means
- The Three Vacuum Ranges and Their Leak Rate Requirements
- How Helium Mass Spectrometer (He-MS) Leak Testing Works
- How to Write Leak Rate Specifications in Your RFQ
- What CNC Machining Quality Is Required to Hold 1×10⁻⁸ mbar·L/s
- Resolution Workflow — When a Chamber Fails the Leak Test
- Prevention Checklist — From Drawing to Leak Test
- Standards & Sources
- Need Precision CNC Machining for Vacuum Chambers?

# Vacuum Chamber Leak Rate — What It Means and How to Specify It in Your RFQ
A semiconductor OEM sends your CNC shop an RFQ for a vacuum chamber. The drawing says “leak rate < 1×10¹&sup9; mbar·L/s”. Your shop has never seen this requirement before. What does it mean? Can your machining actually achieve it? And how do you write vacuum leak specifications into RFQs so that both sides agree on what “pass” looks like? This page answers all three.
## What “Leak Rate < 1×10⁻⁸ mbar·L/s” Actually Means
Leak rate is not pressure. It is a flow rate — the volume of gas (in mbar·L, which is equivalent to Pa·m³) that enters or leaves the chamber per second. A leak rate of 1×10¹&sup9; mbar·L/s means: if you sealed the chamber and waited, gas would seep in at a rate equivalent to 0.000000001 mbar·L every second. To put this in perspective: a single through-hole of 0.1 mm diameter at atmospheric pressure differential produces a leak rate of roughly 1×10¹&sup4; mbar·L/s — 10,000 times the spec. The chamber effectively cannot have any through-path from outside to inside, not even a microscopic porosity path in a weld or a sub-surface crack in a casting.
|  Leak Rate (mbar·L/s) |  Equivalent Hole Size (approx.) |  Typical Application
|  1×10¹³ |  ~1 mm through-hole |  Rough vacuum systems (vacuum packaging, suction cups)
|  1×10¹&sup5; |  ~0.1 mm through-hole |  Industrial vacuum (furnaces, coating chambers)
|  1×10¹&sup7; |  Micro-porosity in weld |  High vacuum (SEM chambers, sputtering systems)
|  1×10¹&sup9; |  Sub-nanometer pathway |  Semiconductor process chambers (CVD, PVD, etch)
|  1×10¹¹ |  Crystal lattice diffusion level |  Ultra-high vacuum (MBE, ion implant, EUV optics)
Draft note (pending Sinbo review) The leak rate ranges and equivalent hole sizes in this page are derived from vacuum engineering fundamentals (Avogadro number, molecular flow regime equations) and cross-checked against INFICON and Pfeiffer Vacuum application notes. Sinbo engineers should validate with actual chamber test data before production translation.
## The Three Vacuum Ranges and Their Leak Rate Requirements
Vacuum technology classifies systems into three main ranges. Each range has different leak rate expectations, different machining requirements, and different test methods:
|  Vacuum Range |  Pressure Range |  Required Leak Rate |  Typical Sealing |  CNC Relevance
|  Rough vacuum |  1000 to 1 mbar |  < 1×10¹&sup5; mbar·L/s |  O-rings (NBR, Viton) |  Standard machining; surface finish Ra 1.6–3.2 μm on seal faces
|  High vacuum (HV) |  10¹³ to 10¹&sup9; mbar |  < 1×10¹&sup9; mbar·L/s |  Metal gaskets (Cu, Al) or knife-edge seals |  Precision machining; seal face Ra < 0.8 μm; flatness < 0.01 mm
|  Ultra-high vacuum (UHV) |  < 10¹&sup9; mbar |  < 1×10¹¹ mbar·L/s |  ConFlat (knife-edge Cu gaskets), welded joints |  Ultra-precision; Ra < 0.4 μm; no subsurface porosity; outgassing-controlled materials
Key insight for CNC shops: The leap from rough vacuum to high vacuum is primarily a sealing surface quality problem. A chamber that holds 1×10¹&sup5; with an O-ring might leak at 1×10¹&sup7; if the O-ring groove has a tool mark deeper than 5 μm. For high vacuum and UHV, the sealing surface must be machined to a mirror finish with no visible tool marks, and the entire chamber must be free of subsurface porosity (which rules out cast chambers without impregnation).
## How Helium Mass Spectrometer (He-MS) Leak Testing Works
The only practical method for measuring leak rates below 1×10¹&sup7; mbar·L/s is helium mass spectrometry (He-MS). Here is how it works: 1- Evacuate the chamber using a turbo-molecular pump backing with a dry scroll pump. Base pressure typically < 1×10¹&sup5; mbar.
1- Connect the chamber to the He-MS leak detector (e.g., Pfeiffer ASM 340, INFICON Quadroro 500, Agilent/Varian 959).
1- Spray helium on the outside of the chamber — along welds, flange seals, feedthroughs, and any potential leak path. Helium is used because: (a) it is inert, (b) it is the smallest atom after hydrogen (easily finds micro-leaks), (c) background helium in air is only 5.24 ppm — any detected helium signal is almost certainly from the spray.
1- The mass spectrometer is tuned to detect helium ions (mass 4). If helium enters the chamber through a leak, the spectrometer detects it and quantifies the flow rate.

|  He-MS Parameter |  Typical Value |  Notes
|  Minimum detectable leak rate (vacuum mode) |  5×10¹¹³ Pa·m³/s (5×10¹¹³ mbar·L/s) |  State-of-the-art instruments (Pfeiffer ASM 340)
|  Minimum detectable leak rate (sniffer mode) |  1×10¹&sup7; Pa·m³/s |  Less sensitive; used for locating large leaks
|  Test gas |  Helium 4.6 (99.996% purity) |  Higher purity reduces background noise
|  Response time |  < 1 second |  Modern instruments
|  Typical test time per chamber |  30–60 minutes |  Includes pump-down + full spray survey
Two test modes. Vacuum mode (chamber evacuated, He sprayed outside): most sensitive, detects total leak rate. Sniffer mode (chamber pressurized with He, probe samples outside): less sensitive but can locate the exact leak position. For semiconductor RFQs, vacuum mode is the standard acceptance test.
## How to Write Leak Rate Specifications in Your RFQ
Most RFQs get the leak rate specification wrong. Here is what a complete vacuum specification looks like: Example RFQ vacuum specification:Leak rate requirement: < 1×10¹&sup9; mbar·L/s (He-MS, vacuum mode)Test method: Helium mass spectrometry per ASTM E498 / ISO 20487Test conditions: Chamber evacuated to base pressure < 5×10¹&sup5; mbar before test. All seals assembled with specified gaskets and torque values.Acceptance criteria: Total leak rate (all paths combined) < 1×10¹&sup9; mbar·L/s. If leak detected, supplier must locate and report leak position(s).Test equipment: Calibrated He-MS leak detector (calibration certificate to be provided with test report).Documentation: Test report including base pressure, helium background, measured leak rate, test duration, and equipment calibration date. Common RFQ mistakes to avoid: - Specifying “vacuum tight” without a numeric leak rate — meaningless
- Specifying leak rate without specifying the test method — a pressure decay test at 1×10¹&sup5; cannot verify 1×10¹&sup9;
- Not specifying the test gas — He-MS is the only method that reaches 10¹&sup9; sensitivity
- Not requiring calibration documentation — an uncalibrated detector may not detect leaks at the required level

## What CNC Machining Quality Is Required to Hold 1×10⁻⁸ mbar·L/s
Achieving a leak rate of 1×10¹&sup9; mbar·L/s is not just about the seal — the chamber body itself must be leak-tight. Here are the machining requirements:
|  Feature |  Requirement for HV (<10⁻⁸) |  Requirement for UHV (<10⁻⁷)
|  Seal face surface finish |  Ra < 0.8 μm |  Ra < 0.4 μm
|  Seal face flatness |  < 0.02 mm |  < 0.005 mm
|  O-ring groove finish |  Ra < 1.6 μm |  Not used (metal seals only)
|  Knife-edge seal geometry |  N/A |  Edge angle 60–90°; edge radius < 5 μm
|  Wall porosity (castings) |  Must be impregnated or use wrought stock |  Wrought stock only; no castings
|  Weld quality |  Full penetration, no porosity; X-ray or dye-pen inspected |  Same + vacuum-fired; outgassing-controlled per ASTM F595
|  Material outgassing |  Not typically specified |  Outgassing rate < 1×10¹¹&sup0; mbar·L/s·cm²
5-axis machining advantage. Complex vacuum chambers with multiple port orientations often require 5-axis machining to achieve the required seal face flatness and perpendicularity in a single setup. Each re-fixturing introduces alignment error that can compromise seal face geometry. 5-axis machining eliminates this by completing all critical features in one clamping.
## Resolution Workflow — When a Chamber Fails the Leak Test
When a chamber fails the He-MS leak test (measured leak rate exceeds spec), follow this workflow: 1- Confirm the test setup. Check: background helium level (should be < 1×10¹¹⁰ mbar·L/s), detector calibration date, pump-down quality (base pressure reached before test). A bad background reading invalidates the test.
1- Locate the leak. Switch to sniffer mode or do a systematic vacuum-mode spray survey: start at flanges, then feedthroughs, then welds, then the body. Record the leak position and approximate magnitude.
1- Classify the leak. (a) Seal leak — at a flange or gasket: re-machine seal face, replace gasket, re-torque to spec. (b) Weld leak — porosity or lack of fusion: re-weld and re-inspect. (c) Body leak — porosity in casting or subsurface defect: impregnate (if casting) or scrap and re-make from wrought stock.
1- Re-test after repair. Every repair must be followed by a full He-MS leak test, not just a spot check at the repaired location. A repair can introduce new leak paths (e.g., thermal distortion from re-welding).
1- Document on the test report. Record: original leak rate, leak location(s), repair action, post-repair leak rate, and final pass/fail.

## Prevention Checklist — From Drawing to Leak Test

|  Stage |  Check |  Why
|  Drawing |  Leak rate specified numerically with test method |  “Vacuum tight” is not a spec
|  Drawing |  Seal face finish and flatness toleranced |  Untoleranced seal faces are the #1 leak source
|  Material selection |  Wrought stock specified for HV/UHV (no castings) |  Casting porosity is a hidden leak path
|  Machining |  Seal faces machined in final setup (no re-fixture) |  Re-fixturing breaks flatness
|  Machining |  Knife-edge geometry verified (angle, edge radius) |  Damaged knife-edge = failed metal seal
|  Assembly |  Gaskets new, clean, correctly torqued |  Reused Cu gaskets leak at HV
|  Pre-test |  All surfaces cleaned per ASTM F595 (solvent clean, bake if UHV) |  Contamination on seal face = leak path
|  Test |  He-MS detector calibration current; background < 10% of spec |  Uncalibrated detector = invalid result

## Standards & Sources
Primary standardsASTM E498 Standard Practice for Helium Mass Spectrometer Leak Detection.ISO 20487 Cleanliness of vacuum components — defines outgassing and particle requirements.ASTM F595 Standard Specification for Vacuum Cleaning and Packaging of Parts for Vacuum Service.ISO 3530 Vacuum technology — Leak detection — defines test methods and sensitivity requirements. Equipment referencesPfeiffer Vacuum ASM 340 Helium mass spectrometer leak detector — minimum detectable leak rate 5×10¹¹³ Pa·m³/s (vacuum mode).INFICON Quadroro 500 Portable He-MS leak detector — used for on-site chamber testing.Agilent/Varian 959 Series High-sensitivity He-MS leak detectors for UHV applications. Frequently Asked Questions What does a leak rate of 1×10⁻⁸ mbar·L/s mean in practice? It means gas enters (or leaves) the chamber at a rate of 0.000000001 mbar·L per second. In practical terms, this is equivalent to saying the chamber has no through-path larger than a sub-nanometer channel — effectively, the entire chamber body and all seals must be impermeable to gas at the molecular level. This is the standard requirement for semiconductor process chambers (CVD, PVD, etch tools). Can a standard CNC machine shop achieve this leak rate? Yes, if the shop has precision machining capability and follows vacuum-grade practices. The key requirements are: (1) seal face surface finish Ra < 0.8 μm for high vacuum, Ra < 0.4 μm for UHV; (2) seal face flatness < 0.01 mm; (3) wrought material stock (no casting porosity); (4) welds that are full-penetration and inspected. 5-axis machining helps by completing all seal features in one setup. The shop does not need to own a He-MS detector — leak testing can be outsourced to a vacuum lab. What is the difference between vacuum mode and sniffer mode He-MS testing? Vacuum mode evacuates the chamber and sprays helium on the outside — it measures the total leak rate but cannot locate individual leaks. Sensitivity: down to 5×10¹¹³ mbar·L/s. Sniffer mode pressurizes the chamber with helium and probes the outside — it can locate individual leaks but is less sensitive (down to ~1×10¹&sup7; mbar·L/s). For semiconductor RFQ acceptance, vacuum mode is the standard. Sniffer mode is used during troubleshooting to find leak positions. What is the most common cause of vacuum chamber leak failures? Seal face machining quality. Tool marks deeper than a few micrometers on a knife-edge or ConFlat flange face create a leak path that no gasket can seal. The second most common cause is casting porosity in chamber bodies — subsurface gas pockets that create micro-channels from inside to outside. For high vacuum and UHV, wrought stock (forged or bar) should always be specified instead of castings. How do I specify vacuum leak rate on an RFQ drawing? Include a note with four elements: (1) numeric leak rate (e.g., < 1×10¹&sup9; mbar·L/s); (2) test method (He-MS, vacuum mode); (3) test conditions (base pressure before test, gasket type, torque values); (4) documentation required (test report with equipment calibration date, background reading, and measured leak rate). Never write “vacuum tight” without a number — it is unenforceable. Do I need to own a helium leak detector to accept vacuum chamber orders? No. Many precision CNC shops outsource He-MS leak testing to specialized vacuum labs or testing services. The critical capability is the machining quality that allows the chamber to pass the test. If you can machine seal faces to Ra < 0.4 μm with flatness < 0.005 mm, and use wrought stock with inspected welds, the chamber will pass — regardless of who performs the leak test. Partner with a local vacuum lab for acceptance testing. What vacuum range does semiconductor equipment typically operate in? Most semiconductor process chambers operate in the high vacuum range (10¹³ to 10¹&sup9; mbar), with leak rate requirements of < 1×10¹&sup9; mbar·L/s. Ultra-high vacuum processes (MBE, ion implant, EUV) operate below 10¹&sup9; mbar and require leak rates < 1×10¹¹ mbar·L/s. The machining requirements for UHV are significantly more stringent: Ra < 0.4 μm, flatness < 0.005 mm, metal seals only, and outgassing-controlled materials. Sources & Standards Referenced 1- ASTM E498: Standard Practice for Helium Mass Spectrometer Leak Detection, ASTM International
1- ISO 20487: Cleanliness of vacuum components — outgassing and particle requirements
1- ISO 3530: Vacuum technology — Leak detection, International Organization for Standardization
1- ASTM F595: Standard Specification for Vacuum Cleaning and Packaging of Parts for Vacuum Service
1- Pfeiffer Vacuum: ASM 340 Helium Mass Spectrometer Leak Detector — technical specifications and application notes (2024)
1- INFICON: Leak Detection — Principles and Practice of Helium Leak Testing (application guide)
1- Joule A. and Calder C.: Vacuum Technology — Scientific and Industrial Applications, Cambridge University Press
1- AVS (American Vacuum Society): Vacuum Chamber Design Guidelines and Leak Testing Best Practices

## Need Precision CNC Machining for Vacuum Chambers?
We machine vacuum chambers from wrought aluminum, 316L stainless, and titanium to high-vacuum specifications. Seal faces to Ra < 0.4 μm, flatness < 0.005 mm, 5-axis capability for complex multi-port designs. Leak testing available through our partner vacuum labs. [Request a Quote ](https://www.sinbo-machining.com/quote/)
